Journal of Equine Veterinary Science
Volume 30, Issue 6 , Pages 287-297, June 2010

Comparison of the Repeatability of Echocardiographic Measurements from Different Modes and Views in Horses of Various Breeds and Sizes

  • Ali Al Haidar, DVM, DEA

      Affiliations

    • Clinical Department of Companion Animals and Equids, Equine Teaching Hospital, Faculty of veterinary Medicine, University of Liège, Belgium
    • Corresponding Author InformationReprint requests: Ali Al Haidar, PhD student, Equine Teaching Hospital, Clinical Department of Companion Animals and Equips, Faculty of Veterinary Medicine, University of Liège, Bat. B.41. Sart-Tilman, B4000 Liège, Belgium.
  • ,
  • Frédéric Farnir, PhD, Professor

      Affiliations

    • Biostatistics, Bioinformatics, Economics and Animal Selection, Department of Animal Production, Faculty of veterinary Medicine, University of Liège, Belgium
  • ,
  • Stefan Deleuze, DVM, PhD, Dipl. ECAR

      Affiliations

    • Clinical Department of Companion Animals and Equids, Equine Teaching Hospital, Faculty of veterinary Medicine, University of Liège, Belgium
  • ,
  • Charlotte Sandersen, DVM, PhD, Dipl. ECEIM

      Affiliations

    • Clinical Department of Companion Animals and Equids, Equine Teaching Hospital, Faculty of veterinary Medicine, University of Liège, Belgium
  • ,
  • H. Amory, DVM, PhD, Dipl. ECIM

      Affiliations

    • Clinical Department of Companion Animals and Equids, Equine Teaching Hospital, Faculty of veterinary Medicine, University of Liège, Belgium

Abstract 

The objective of this study was to compare the repeatability of echocardiographic measurements obtained from different echocardiographic modes and views in healthy adult equids of various sizes, breeds, and thorax shapes. Ten equids (body weight: 120–662 kg; age: 1–26 years) from various breeds, free of cardiac disease, were used in this study. Each animal was submitted to a standardized echocardiographic and Doppler protocol 3 times at 1 day interval. This protocol included the measurements of left and right ventricular, aortic, pulmonary, and left atrial parameters obtained from different views using the bidimensional (2D) or the motion (M) modes, and the measurement of several parameters of blood flow obtained from the pulsed wave Doppler mode. Repeatability of each measurement was estimated on the basis of the residual variance using a linear model and the coefficient of variation of repeated measurements. A two by two comparison of the repeatability of measurements performed in different views was performed using the residual variances in a variance ratio F test. Results showed that repeatability of echocardiographic or Doppler measurements in equids of various sizes, breeds, and thorax shapes are comparable to previously reported results in thoroughbred and standardbred horses. Left ventricular morphologic parameters showed a good repeatability in the classic M-mode right parasternal short axis view at the level of the chordae tendineae, but the 2D-mode right parasternal long axis four-chamber view appeared to offer an interesting alternative measurement. This latter view also allowed obtaining the most repeatable measurement of right ventricular internal diameter. The left atrial diameter was maximal and most repeatable in the 2D-mode left parasternal long axis four-chamber angled view, and the repeatability of the aortic diameter was best in the 2D-mode right parasternal long axis five-chamber view. Finally, aortic systolic time intervals were more repeatable when measured from the Doppler mode as compared with the M-mode. In conclusion, repeatability of echocardiographic measurements in horses could be optimized after the following protocol: (1) M-mode right parasternal short axis view at the level of chordae tendineae to measure left ventricular morphologic parameters, and 2D-mode right parasternal long axis four-chamber as an alternative view; (2) 2D-mode right parasternal long axis five-chambers to measure the aortic diameter; (3) 2D-mode left parasternal long axis four-chambers angled view to measure the left atrial diameter.

Keywords: Echocardiography, Repeatability, 2D-mode, M-mode, Doppler measurements

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0737-0806(10)00206-6

doi:10.1016/j.jevs.2010.04.004

Journal of Equine Veterinary Science
Volume 30, Issue 6 , Pages 287-297, June 2010