Journal of Equine Veterinary Science
Volume 27, Issue 4 , Pages 161-166 , April 2007

The Accuracy and Precision of an Equine In-Shoe Pressure Measurement System as a Tool for Gait Analysis

  • V.V. Perino
  • ,
  • C.E. Kawcak

      Affiliations

    • Corresponding Author InformationReprint requests: Chris E. Kawcak, DVM, PhD, Gail Holmes Equine Orthopaedic Research Center, Department of Clinical Sciences, 300 West Drake Road, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO 80523.
  • ,
  • D.D. Frisbie
  • ,
  • R.F. Reiser
  • ,
  • C.W. McIlwraith

References 

  1. USDA. Lameness and laminitis in U.S. horses. In: USDA: Aphis: VS, CEAH, National Animal Health Monitoring System, Fort Collins, CO; 2000:1-6.
  2. Leach DH, Dagg AI. A review of research on equine locomotion and biomechanics. Equine Vet J. 1983;15:93–102
  3. Barrey E. Methods, applications and limitations of gait analysis in horses. Vet J. 1999;157:7–22
  4. Clayton HM. Instrumentation and techniques in locomotion and lameness. Vet Clin North Am Equine Pract. 1996;12:337–350
  5. Leach D. Noninvasive technology for assessment of equine locomotion. In: Lameness in equine practice. Trenton, NJ: Veterinary Learning Systems; 1993;p. 180–190
  6. Merkens HW, Schamhardt HC, Kersjes AW. Ground reaction force patterns of Dutch warmblood horses at normal walk. Equine Vet J. 1985;18:207–214
  7. Dow SM, Leendertz JA, Silver IA, Goodship AE. Identification of subclinical tendon injury from ground force reaction analysis. Equine Vet J. 1991;23:266–272
  8. Young CR. The F-scan system of foot pressure analysis. Clin Podiatr Med Surg. 1993;10:455–461
  9. Bontrager EL. Instrumented gait analysis systems. In: Gait analysis in the science of rehabilitation. Washington, DC: US Department of Veteran Affairs; 1998;2:11–32
  10. Frederick EC, Hartner KP. The evolution of foot pressure measurements. Sensors. 1993;30–35
  11. McPoil TG, Cornwall MW, Yamanda W. A comparison of two in-shoe plantar pressure measurement systems. Lower Extremity. 1995;2:95–103
  12. Alexander IJ, Chao EYS, Johnson KA. The assessment of dynamic foot-to-ground contact forces and plantar pressure distribution: a review of the evolution of current techniques and clinical applications. Foot and Ankle. 1990;11:152–167
  13. Carter JE, Galuppo LD, Snyder JR, Willitis NH. Evaluation of an in-shoe pressure measurement system in horses. Am J Vet Res. 2001;62:23–27
  14. Franks JN, Boothe HW, Taylor L, Geller S, Carroll GL, Cracas V, et al. Evaluation of transdermal fentanyl patches for analgesia in cats undergoing onychectomy. J Am Vet Med Assoc. 2000;217:1013–1020
  15. Perino VV. The Tekscan system: a tool for objectively measuring lameness in the horse. MS Thesis. Fort Collins, CO: Colorado State University; 2002;1–60
  16. Perino VV. Comparing pressure measurement systems and a force platform as tools for equine gait analysis. PhD Dissertation. Fort Collins, CO: Colorado State University; 2007;in press
  17. Hsiao H, Guan J, Weatherly M. Accuracy and precision of two in-shoe pressure measurment systems. Ergonomics. 2002;45:537–555
  18. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet. 1986;307–310
  19. Seeherman HJ, Morris EA, Fackelman GE. Computerized force plate determination of equine weightbearing profiles. Equine Exerc Physiol. 1987;2:537–552
  20. Randolph AL, Nelson M, Akkapeddi S, Levin A, Alexandrescu R. Reliability of measurements of pressures applied on the foot during walking by a computerized insole sensor system. Arch Phys Med Rehabil. 2000;81:573–578

 Refereed

PII: S0737-0806(07)00083-4

doi: 10.1016/j.jevs.2007.02.006

Journal of Equine Veterinary Science
Volume 27, Issue 4 , Pages 161-166 , April 2007