Journal of Equine Veterinary Science
Volume 27, Issue 4 , Pages 161-166, April 2007

The Accuracy and Precision of an Equine In-Shoe Pressure Measurement System as a Tool for Gait Analysis

  • V.V. Perino
  • ,
  • C.E. Kawcak

      Affiliations

    • Corresponding Author InformationReprint requests: Chris E. Kawcak, DVM, PhD, Gail Holmes Equine Orthopaedic Research Center, Department of Clinical Sciences, 300 West Drake Road, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO 80523.
  • ,
  • D.D. Frisbie
  • ,
  • R.F. Reiser
  • ,
  • C.W. McIlwraith

From the Gail Holmes Equine Orthopaedic Research Center, Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, Colorado

Abstract 

Normal horses with no clinical lameness were studied to test the hypothesis that Equine F-Scan sensors (EFS) would produce vertical force data that correlated highly with vertical force data from a force platform. Six horses were trotted across a force platform while wearing the EFS. Vertical force measurements were recorded from each system with data analyzed from hoof strikes that occurred simultaneously on both systems. Coefficients of variation (CV) were evaluated to test precision of the systems. The CV of the EFS was 10.2%, compared with 6.6% for the force platform. The accuracy of the pressure measurement system was tested by measuring agreement and a paired t test. The test for measuring agreement showed large differences between measuring devices, indicating an overall lack of agreement between measurements from the two systems, with differences ranging from 9 Newtons (N) to 1,200 N. Results from a paired t test, however, showed no significant difference between measurements from the two devices as noted by a P-value of .294, indicating a lack of significant differences because of assessment of averaged data. Because of the inability of the EFS to provide precise measurements of vertical ground reaction force as noted by high coefficients of variation and an overall lack of agreement between measurements from the two systems, this system should not be used to objectively measure vertical force in horses in its current format.

Keywords: Pressure measurement, Force platform, Gait assessment

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Refereed

PII: S0737-0806(07)00083-4

doi:10.1016/j.jevs.2007.02.006

Journal of Equine Veterinary Science
Volume 27, Issue 4 , Pages 161-166, April 2007